Characteristic:

Voltage: 33~38kV

Current: 100A/200A/300A

Creepage: 1080mm

Standard: IEC60282-2

    Description

    FSC series drop out cutout with standard fuse link protects the transformer, capacitors, cables or lines from the short circuit and over load in 11KV~38KV overhead distribution systems. Dropout Fuse Cutout is a kind of outdoor used high voltage protective device.To be connected with incoming feeder of distribution transformer or distribution line it mainly protect transformer or lines from short circuit and overload,and on/off loading current.
    Dropout Fuse Cutout is composed of insulator supports and fuse tube,static contacts is fixed on two sides of insulator support and moving contact is installed on two ends of fuse tube.Fuse tube is composed of inside extinguishing tube,outer phenol compound paper tube or epoxy glass tube.Load switching fuse cutout provides enforced elastic auxiliary contacts and arc-extinguishing enclosure for switching on/offloading current.At normally working via fuse link tightened the fuse tube is fixed to form up of close position.In case system occur faults,fault current result in fuse melt immediately and take place electric arc,which let arc-extinguishing tube being heated and explode a lot of gas.This will produce high pressure and blow off the arc along with tube.
    After fuse link melt moving contact has no tightened strength again,mechanism is locked and fuse tube dropout.Cutout now is in open position.
    When it needs to switch off during cut out loading.Operator shall via insulating operating bar pull the moving contact,at its beginning main contact and auxiliary static contact is contacted still.
    Whiling pulling the auxiliary contact is separated between auxiliary contacts there occur electric arc and the arc will be lengthened in arc-extinguishing enclosure gap and meanwhile arc-extinguishing explode gas to blow off the arc during current passing zero.

    Main features

    Electrical characteristics

    Specification

    Unit

    Voltage

    33~38

    KV

    Current

    100/200/300

    A

    Frequency

    50/60

    Hz

    Power frequency withstand voltage to earth (1 min)

    70

    KV

    Power frequency withstand voltage phase to phase (1 min)

    80

    KV

    Impulse voltage to earth

    170

    KV

    Impulse voltage phase to phase

    180

    KV

    Breaking current

    6

    KA

    Creepage distance:

    1080

    mm

    Spare parts

    Mounting bracket

    with/without

    Arc shortening rod

    with/without

    Arc distinguish chamber

    with/without

    Fuse link

    without

    Material

    Copper content for brass

    Brass (60~62%)

    Conductive parts material

    Copper with silver plated/Copper with tin plate

    Insulator

    Porcelain/Polymer

    Fuse tube

    Fiber glass

    Package

    Qty/package

    1

    pc/carton

    Service conditions

    Environment maximum temperature

    40

    Pollution level

    II

    Altitude

    ≤1000

    Meter

    Standard

    IEC60282-2

    Fuse cutout structure

    Main bearing structure and main bearing structure

    fuse-structure-1xas

    Fuse cutout accessories

    Including lower general bearing of fuse, arc extinguishing housing, American type fusible load with knife and 300A fusible load

    fuse-accessories-1cgr

    description2